Mining Cable | 15KV

Contact Us


Las Vegas, NV


Phone: (800) 827-1144

Phone: (702) 639-4000

Fax: (702) 639-4001




Reno, NV


Phone: (800) 827-6116

Phone: (775) 850-3000

Fax: (775) 850-3001

Mine Power Feeder

Type MPF-GC Three Conductor
XLP/PVC 15 kV
mining cable

mining cable mine power feeder
A P P L I C A T I O N S
1.
2.
3.
Primary power distribution in mines
Used in boreholes, shafts and horizontal runs
High voltage power applications wet or dry
4.
5.
Aerially suspended on insulators
Semi permanent power
S P E C I F I C A T I O N S
1.

2.

3.
4.
5.
Conductor: Stranded soft-drawn uncoated copper
Conductor Shield: Extruded semi-conducting layer
Insulation:
Cross-linked polyethylene (XLP)*
Shield: Copper tape over semi-conducting layer
Ground Conductors:
Two stranded soft-drawn coated copper conductors
6.

7.
8.
9.
10.
11.
Ground Check: Stranded coated copper with yellow insulation
Jacket:
Polyvinyl chloride (PVC)*
Temperature:
90°C
Voltage:
15000 Volts
Color Code:
Chart No. 4 **
Industry Approvals
:
MSHA, ICEA, NEMA
Part
No.
Size
AWG/
MCM
No.
of
Cond.
No. of
Strnd ¤
Grnd.
Cond.
Size
AWG
Grnd
Check
Size
AWG
Insul.
Thick.
in.
Jckt.
Thick.
in.
Approx.
O.D.
inches
Amp.§
Rate
Approx.
Weight
lbs/Mft
100% Insulation Level
08-EN-3803 2 3 7 6 8 .080 .140 1.88 164 2020
08-EN-3903 1 3 19 5 8 .080 .140 1.94 187 2299
08-EN-4003 1/0 3 19 4 8 .080 .140 2.03 215 2639
08-EN-4103 2/0 3 19 3 8 .080 .140 2.13 246 3068
08-EN-4203 3/0 3 19 2 8 .080 .140 2.23 283 3584
08-EN-4303 4/0 3 19 1 8 .080 .140 2.36 325 4254
08-EN-4403 250 3 37 1/0 8 .080 .140 2.48 359 4871
08-EN-4803 350 3 37 2/0 8 .080 .140 2.70 438 6209
08-EN-5303 500 3 37 4/0 8 .080 .170 3.05 536 8476
133% Insulation Level
08-EP-3903 1 3 19 5 8 .080 .140 2.15 187 2965
08-EP-4003 1/0 3 19 4 8 .080 .140 2.20 215 3315
08-EP-4103 2/0 3 19 3 8 .080 .140 2.30 246 3965
08-EP-4203 3/0 3 19 2 8 .080 .140 2.45 283 4460
08-EP-4303 4/0 3 19 1 8 .080 .140 2.55 325 5205
08-EP-4403 250 3 37 1/0 8 .080 .140 2.65 359 5725
08-EP-4803 350 3 37 2/0 8 .080 .170 2.95 438 7520
08-EP-5303 500 3 37 4/0 8 .080 .170 3.25 536 9955
* Available with thermoset insulation and jacket
** Other methods of conductor identification available
¤ Other strand counts available
§ Ampacities per ICEA/NEMA (refer to NEC handbook for National Electrical Code Ampacities).

 