High Voltage Cable | Unshielded - Three Conductor

Contact Us


Las Vegas, NV


Phone: (800) 827-1144

Phone: (702) 639-4000

Fax: (702) 639-4001




Reno, NV


Phone: (800) 827-6116

Phone: (775) 850-3000

Fax: (775) 850-3001

EPR / PVC

Three Conductor-Non-Shielded
AEIC CS-6 MV-90 5kV

high voltage cable

high voltage EPR/PVC 5KV
A P P L I C A T I O N S
1.
2.
3.
4.
5.
Raceways
Aerial (when properly supported)
Industrial plants
Primary power and distribution circuits
Utility substations
6.
7.
8.
9.
10.
Generating plants
Wet or dry locations
Conduit, ducts, open tray or free air
Direct burial
Feeders, distribution, and branch circuits
S P E C I F I C A T I O N S
1.
2.

3.
4.
5.
6.
Conductors: Stranded soft-drawn bare copper
Conductor Shield: Semi-conducting compound or tape
Insulation: Ethylene propylene rubber (EPR)
Ground Wire: Stranded bare copper**
Cabling: suitable lay with fillers
Jacket: Sunlight resistant polyvinyl
chloride (PVC)
7.

8.

9.
Temperature: 90°C continuous,
130°C emergency, 250°C short circuit
Voltage: 5000 Volts 100% & 133% insulation level
Industry Approvals:
UL 1072 listed type MV-90
ICEA S-68-516
NEMA WC8
AEIC CS-6
Part
Number
Size
AWG/
MCM
No. of
Strands
Ground
Size
AWG
Insul.
Thick.
in
Jacket
Thick.
in
Approx.
O.D.
inches
Ampa-
city*
Rating
Approx.
Weight
lbs/Mft
100% & 133% Insulation
04-FA-3207 8 7 8 .090 .080 1.07 59 580
04-FA-3407 6 7 6 .090 .080 1.15 79 789
04-FA-3607 4 7 6 .090 .080 1.26 105 1012
04-FA-3807 2 7 6 .090 .080 1.39 140 1359
04-FA-3919 1 19 4 .090 .080 1.47 160 1579
04-FA-4019 1/0 19 4 .090 .080 1.56 185 1869
04-FA-4119 2/0 19 4 .090 .080 1.66 215 2124
04-FA-4219 3/0 19 3 .090 .110 1.83 250 2774
04-FA-4319 4/0 19 3 .090 .110 1.95 285 3303
04-FA-4437 250 37 3 .090 .110 2.10 320 3804
04-FA-4637 300 37 2 .090 .110 2.26 355 4404
04-FA-4837 350 37 2 .090 .110 2.33 395 5003
04-FA-5037 400 37 2 .090 .110 2.45 420 5760
04-FA-5337 500 37 1 .090 .110 2.61 485 6416
04-FA-5661 600 61 1 .090 .140 2.98 540 8005
04-FA-6061 750 61 1/0 .090 .140 3.13 615 9493
04-FA-6561 1000 61 1/0 .090 .140 3.40 705 11875
* Amps per conductor is in accordance with NEC table 310-71, for three conductor copper cable isolated in air, based on a conductor temperature of 90°C and ambient temperature of 40°C. For other installation conditions, refer to the National Electrical Code.
** Special ground wire configurations are available upon request
NOTE: May also be available with a Hypalon Jacket.

 