High Voltage Cable | Single Conductor

Contact Us


Las Vegas, NV


Phone: (800) 827-1144

Phone: (702) 639-4000

Fax: (702) 639-4001




Reno, NV


Phone: (800) 827-6116

Phone: (775) 850-3000

Fax: (775) 850-3001

XLP / PVC

Single Conductor Shielded
AEIC CS-5 MV-90 15kV

high voltage cable

high voltage XLP/PVC 15KV
A P P L I C A T I O N S
1.
2.
3.
4.
Raceways
Aerial (when properly supported)
Industrial Plants
Primary power & distribution circuits
5.
6.
7.
8.
9.
Utility substations
Generating plants
Wet or dry locations
Conduit, ducts, open tray, or open air
Direct burial
S P E C I F I C A T I O N S
1.
2.

3.
4.

5.
Conductor: Stranded soft-drawn bare copper
Conductor Shields: Semi-conducting compound or tape
Insulation: Cross-linked polyethylene (XLP)
Insulation Shield: Semi-conducting tape with concentrically wrapped bare copper wires
Jacket: Polyvinyl chloride (PVC)
6.

7.

8.
Temperature: 90°C continuous,
130°C emergency, 250°C short circuit
Voltage: 15000 Volts 100% & 133% insulation level
Industry Approvals:
UL 1072 listed MV-90 Wet or Dry,
ICEA S-66-524, NEMA WC 7,
AEIC CS-5
Part Number Size
AWG/
MCM
No. of
Strands
Insul.
Thick.
in
Jacket
Thick.
in
Approx.
O.D.
inches
Ampacity*
Rating
Approx.
Weight
lbs/Mft
100% Insulation Level
04-BA-1338 2 7 .175 .080 .097 150 515
04-BA-1339 1 19 .175 .080 1.02 170 590
04-BA-1340 1/0 19 .175 .080 1.06 195 675
04-BA-1341 2/0 19 .175 .080 1.10 225 785
04-BA-1342 3/0 19 .175 .080 1.14 260 915
04-BA-1343 4/0 19 .175 .080 1.21 295 1085
04-BA-1344 250 37 .175 .080 1.27 330 1235
04-BA-1348 350 37 .175 .080 1.37 395 1600
04-BA-1353 500 37 .175 .080 1.50 480 2135
04-BA-1360 750 61 .175 .080 1.72 585 3015
04-BA-1365 1000 61 .175 .110 1.94 675 3990
133% Insulation Level
04-BB-1338 2 7 .220 .080 1.07 150 580
04-BB-1339 1 19 .220 .080 1.11 170 645
04-BB-1340 1/0 19 .220 .080 1.15 195 745
04-BB-1341 2/0 19 .220 .080 1.20 225 850
04-BB-1342 3/0 19 .220 .080 1.25 260 985
04-BB-1343 4/0 19 .220 .080 1.30 295 1150
04-BB-1344 250 37 .220 .080 1.36 330 1300
04-BB-1348 350 37 .220 .080 1.47 395 1670
04-BB-1353 500 37 .220 .080 1.60 480 2175
04-BB-1360 750 61 .220 .110 1.89 585 3180
04-BB-1365 1000 61 .220 .110 2.05 675 4105
* Amps per conductor is in accordance with NEC table 310-73, for three conductors in an isolated conduit in air, based on a conductor temperature of 90°C and ambient temperature of 40°C. For other installation conditions, refer to the National Electrical Code.
NOTE: May also be available with a Hypalon Jacket.

 

JCH Wire & Cable... striving to exceed